Inverter Omron 3G3RX2
Kami Jual Inverter Omron 3G3RX2 berkualitas Original dan dijamin keasliannya. Omron adalah merk dagang terkemuka yang telah dipakai hampir di semua pabrik yang ada di Indonesia. Kami siap memenuhi kebutuhan inverter Omron untuk Anda dengan cepat dengan harga bersaing di seluruh Indonesia.
Inverter Omron 3G3RX2 Description
Evolved Heritage
This high performance inverter offers the same usability as the previous model, which allows easy replacement.
Easy replacement
Inverter Omron 3G3RX2 Series with the same mounting dimension as the previous model will fit in the existing control panel or mounting location. In addition, the same setting software CX-Drive can be used for the RX2 Series. Parameter settings and programs used for the previous model can be easily converted and transferred to the RX2 Series.
Note: The depth of some models may vary.

Built-in EMC Filter
Built-in noise filters corresponding to the European EMC Directive IEC61800-3 2nd Environment Category C3 and UL Power Conversion Equipment/UL61800-5-1 will save external hardware and extra cost.

Usability Evolving
Inverter Omron 3G3RX2 Series delivers improved usability: more efficient, easier, and faster.
Easy setup and operation
The new full-color LCD operator, which replaced the previous 7-segment display, makes setup and operation more intuitive and easier. The parameter copy function of the operator allows you to quickly copy parameter settings to other RX2 Inverters.

Application customized
Inverter Omron 3G3RX2 Inverter can perform simple sequence control programmed using support software CX-Drive.
Crane control, tension control, and other large-scale processes that require fast control speeds can be configured without a PLC, optimizing costs.

In Constant Evolution
The RX2 Series continues to evolve, meeting ever-changing demands and helping improve productivity.
PM motor control
The RX2 Series can control permanent magnet motors (PM motors) as well as induction motors. Auto-tuning maximizes PM motor performance, helping save energy.

Safety embedded
The RX2 Series features Safe Torque Off (STO) as standard to meet your machine safety needs.
・STO according to IEC 61800-5-2:2016
・PLe and CAT 4 according to EN ISO 13849-1:2015
・SIL3 according to IEC 61508:2010 and EN/IEC 62061:2012

EtherCAT®
The EtherCAT option is available. Connect the RX2 Inverters with the NX/NJ Machine Automation Controller to improve development and production productivity.
Both conf igurations are possible, s tandard and Ring topology.

Minimize time to market
One Integrated Development Environment Software.
・ One software to integrate
・ Work as a team
・ Integrated commissioning tools
・ Sysmac troubleshooter
・ Multiple configurations
・ Open Standards

Inverter Omron 3G3RX2 Spesifications
Inverter 3G3RX2
3-phase 200-V Class
Very Low Duty (VLD)/Low Duty (LD)/Normal Duty (ND)
3G3RX2-A2[][][][][] | A2004 | A2007 | A2015 | A2022 | A2037 | |||
---|---|---|---|---|---|---|---|---|
Applicable motor (4-pole) capacity (kW) | VLD | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | ||
LD | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | |||
ND | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | |||
Output | Rated output current (A) | VLD | 4.4 | 8.0 | 10.4 | 15.6 | 22.8 | |
LD | 3.7 | 6.3 | 9.4 | 12.0 | 19.6 | |||
ND | 3.2 | 5.0 | 8.0 | 11.0 | 17.5 | |||
Overload current rating | VLD | 110% 60 sec / 120% 3 sec | ||||||
LD | 120% 60 sec / 150% 3 sec | |||||||
ND | 150% 60 sec / 200% 3 sec | |||||||
Rated output voltage | 3-phase (3-wire) 200 to 240 V (depending on receiving voltage) | |||||||
Rated capacity (kVA) | 200 V | VLD | 1.5 | 2.8 | 3.6 | 5.4 | 7.9 | |
LD | 1.3 | 2.2 | 3.3 | 4.2 | 6.8 | |||
ND | 1.1 | 1.7 | 2.8 | 3.8 | 6.1 | |||
240 V | VLD | 1.8 | 3.3 | 4.3 | 6.5 | 9.5 | ||
LD | 1.5 | 2.6 | 3.9 | 5.0 | 8.1 | |||
ND | 1.3 | 2.1 | 3.3 | 4.6 | 7.3 | |||
Input | Rated input current (A) *1 | VLD | 5.2 | 9.5 | 12.4 | 18.6 | 27.1 | |
LD | 4.4 | 7.5 | 11.2 | 14.3 | 23.3 | |||
ND | 3.8 | 6.0 | 9.5 | 13.1 | 20.8 | |||
Rated input AC voltage | Control power supply: Power supply single phase 200 to 240 V/allowable variation range 170 to 264 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | |||||||
Main circuit power supply: 3-phase (3-wire) 200 to 240 V/allowable variation range 170 to 264 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | ||||||||
Power supply equipment capacity (kVA) *2 | VLD | 2.0 | 3.6 | 4.7 | 7.1 | 10.3 | ||
LD | 1.7 | 2.9 | 4.3 | 5.4 | 8.9 | |||
ND | 1.5 | 2.3 | 3.6 | 5.0 | 7.9 | |||
Carrier frequency operating range *3 | VLD | 0.5 to 10.0 kHz | ||||||
LD | 0.5 to 12.0 kHz | |||||||
ND | 0.5 to 16.0 kHz | |||||||
Motor start torque *4 | 200%/0.3 Hz | |||||||
Braking | Regenerative braking | Equipped with BRD circuit (with a discharging resistor separately installed) | ||||||
Minimum resistance that can be connected (Ω) | 50 | 50 | 35 | 35 | 35 | |||
Dimension | Height (mm) | 255 | 255 | 255 | 255 | 255 | ||
Width (mm) | 150 | 150 | 150 | 150 | 150 | |||
Depth (mm) | 140 | 140 | 140 | 140 | 140 | |||
Protective construction | IP20 *5 / UL open type | |||||||
Approximate mass (kg) | 3 | 3 | 3 | 3 | 3 |
3G3RX2-A2[][][][][] | A2055 | A2075 | A2110 | A2150 | A2185 | |||
---|---|---|---|---|---|---|---|---|
Applicable motor (4-pole) capacity (kW) | VLD | 7.5 | 11 | 15 | 18.5 | 22 | ||
LD | 7.5 | 11 | 15 | 18.5 | 22 | |||
ND | 5.5 | 7.5 | 11 | 15 | 18.5 | |||
Output | Rated output current (A) | VLD | 33.0 | 46.0 | 60.0 | 80.0 | 93.0 | |
LD | 30.0 | 40.0 | 56.0 | 73.0 | 85.0 | |||
ND | 25.0 | 32.0 | 46.0 | 64.0 | 76.0 | |||
Overload current rating | VLD | 110% 60 sec / 120% 3 sec | ||||||
LD | 120% 60 sec / 150% 3 sec | |||||||
ND | 150% 60 sec / 200% 3 sec | |||||||
Rated output voltage | 3-phase (3-wire) 200 to 240 V (depending on receiving voltage) | |||||||
Rated capacity (kVA) | 200 V | VLD | 11.4 | 15.9 | 20.8 | 27.7 | 32.2 | |
LD | 10.4 | 13.9 | 19.4 | 25.3 | 29.4 | |||
ND | 8.7 | 11.1 | 15.9 | 22.2 | 26.3 | |||
240 V | VLD | 13.7 | 19.1 | 24.9 | 33.3 | 38.7 | ||
LD | 12.5 | 16.6 | 23.3 | 30.3 | 35.3 | |||
ND | 10.4 | 13.3 | 19.1 | 26.6 | 31.6 | |||
Input | Rated input current (A) *1 | VLD | 39.3 | 54.8 | 71.4 | 95.2 | 110.7 | |
LD | 35.7 | 47.6 | 66.7 | 86.9 | 101.2 | |||
ND | 29.8 | 38.1 | 54.8 | 76.2 | 90.5 | |||
Rated input AC voltage | Control power supply: Power supply single phase 200 to 240 V/allowable variation range 170 to 264 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | |||||||
Main circuit power supply: 3-phase (3-wire) 200 to 240 V/allowable variation range 170 to 264 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | ||||||||
Power supply equipment capacity (kVA) *2 | VLD | 15.0 | 20.9 | 27.2 | 36.3 | 42.2 | ||
LD | 13.6 | 18.1 | 25.4 | 33.1 | 38.6 | |||
ND | 11.3 | 14.5 | 20.9 | 29.0 | 34.5 | |||
Carrier frequency operating range *3 | VLD | 0.5 to 10.0 kHz | ||||||
LD | 0.5 to 12.0 kHz | |||||||
ND | 0.5 to 16.0 kHz | |||||||
Motor start torque *4 | 200%/0.3 Hz | |||||||
Braking | Regenerative braking | Equipped with BRD circuit (with a discharging resistor separately installed) | ||||||
Minimum resistance that can be connected (Ω) | 16 | 10 | 10 | 7.5 | 7.5 | |||
Dimension | Height (mm) | 260 | 260 | 260 | 390 | 390 | ||
Width (mm) | 210 | 210 | 210 | 245 | 245 | |||
Depth (mm) | 170 | 170 | 170 | 190 | 190 | |||
Protective construction | IP20 *5 / UL open type | |||||||
Approximate mass (kg) | 6 | 6 | 6 | 10 | 10 |
3G3RX2-A2[][][][][] | A2220 | A2300 | A2370 | A2450 | A2550 | |||
---|---|---|---|---|---|---|---|---|
Applicable motor (4-pole) capacity (kW) | VLD | 30 | 37 | 45 | 55 | 75 | ||
LD | 30 | 37 | 45 | 55 | 75 | |||
ND | 22 | 30 | 37 | 45 | 55 | |||
Output | Rated output current (A) | VLD | 124 | 153 | 185 | 229 | 295 | |
LD | 113 | 140 | 169 | 210 | 270 | |||
ND | 95.0 | 122 | 146 | 182 | 220 | |||
Overload current rating | VLD | 110% 60 sec / 120% 3 sec | ||||||
LD | 120% 60 sec / 150% 3 sec | |||||||
ND | 150% 60 sec / 200% 3 sec | |||||||
Rated output voltage | 3-phase (3-wire) 200 to 240 V (depending on receiving voltage) | |||||||
Rated capacity (kVA) | 200 V | VLD | 43.0 | 53.0 | 64.1 | 79.3 | 102.2 | |
LD | 39.1 | 48.5 | 58.5 | 72.7 | 93.5 | |||
ND | 32.9 | 42.3 | 50.6 | 63.0 | 76.2 | |||
240 V | VLD | 51.5 | 63.6 | 76.9 | 95.2 | 122.6 | ||
LD | 47.0 | 58.2 | 70.3 | 87.3 | 112.2 | |||
ND | 39.5 | 50.7 | 60.7 | 75.7 | 91.5 | |||
Input | Rated input current (A) *1 | VLD | 147.6 | 182.1 | 220.2 | 272.6 | 351.2 | |
LD | 134.5 | 166.7 | 201.2 | 250.0 | 321.4 | |||
ND | 113.1 | 145.2 | 173.8 | 216.7 | 261.9 | |||
Rated input AC voltage | Control power supply: Power supply single phase 200 to 240 V/allowable variation range 170 to 264 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | |||||||
Main circuit power supply: 3-phase (3-wire) 200 to 240 V/allowable variation range 170 to 264 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | ||||||||
Power supply equipment capacity (kVA) *2 | VLD | 56.3 | 69.4 | 83.9 | 103.9 | 133.8 | ||
LD | 51.3 | 63.5 | 76.7 | 95.3 | 122.5 | |||
ND | 43.1 | 55.3 | 66.2 | 82.6 | 99.8 | |||
Carrier frequency operating range *3 | VLD | 0.5 to 10.0 kHz | ||||||
LD | 0.5 to 12.0 kHz | |||||||
ND | 0.5 to 16.0 kHz | |||||||
Motor start torque *4 | 200%/0.3 Hz | |||||||
Braking | Regenerative braking | Equipped with BRD circuit (with a discharging resistor separately installed) | Regenerative braking unit separately installed | |||||
Minimum resistance that can be connected (Ω) | 5 | — | — | — | — | |||
Dimension | Height (mm) | 390 | 540 | 550 | 550 | 700 | ||
Width (mm) | 245 | 300 | 390 | 390 | 480 | |||
Depth (mm) | 190 | 195 | 250 | 250 | 250 | |||
Protective construction | IP20 *5 / UL open type | |||||||
Approximate mass (kg) | 10 | 22 | 33 | 33 | 47 |
3-phase 400-V Class
Very Low Duty (VLD)/Low Duty (LD)/Normal Duty (ND)
3G3RX2-[][][][][] | A4007 | A4015 | A4022 | A4037 | A4055 | A4075 | |||
---|---|---|---|---|---|---|---|---|---|
Applicable motor (4-pole) capacity (kW) | VLD | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | ||
LD | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | |||
ND | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | |||
Output | Rated output current (A) | VLD | 4.1 | 5.4 | 8.3 | 12.6 | 17.5 | 25.0 | |
LD | 3.1 | 4.8 | 6.7 | 11.1 | 16.0 | 22.0 | |||
ND | 2.5 | 4.0 | 5.5 | 9.2 | 14.8 | 19.0 | |||
Overload current rating | VLD | 110% 60 sec / 120% 3 sec | |||||||
LD | 120% 60 sec / 150% 3 sec | ||||||||
ND | 150% 60 sec / 200% 3 sec | ||||||||
Rated output voltage | 3-phase (3-wire) 380 to 500 V (depending on receiving voltage) | ||||||||
Rated capacity (kVA) | 400 V | VLD | 2.8 | 3.7 | 5.8 | 8.7 | 12.1 | 17.3 | |
LD | 2.1 | 3.3 | 4.6 | 7.7 | 11.1 | 15.2 | |||
ND | 1.7 | 2.8 | 3.8 | 6.4 | 10.3 | 13.2 | |||
500 V | VLD | 3.6 | 4.7 | 7.2 | 10.9 | 15.2 | 21.7 | ||
LD | 2.7 | 4.2 | 5.8 | 9.6 | 13.9 | 19.1 | |||
ND | 2.2 | 3.5 | 4.8 | 8.0 | 12.8 | 16.5 | |||
Input | Rated input current (A) *1 | VLD | 4.9 | 6.4 | 9.9 | 15.0 | 20.8 | 29.8 | |
LD | 3.7 | 5.7 | 8.0 | 13.2 | 19.0 | 26.2 | |||
ND | 3.0 | 4.8 | 6.5 | 11.0 | 17.6 | 22.6 | |||
Rated input AC voltage | Control power supply: Power supply single phase 380 to 500 V (allowable variation range 323 to 550 V), 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | ||||||||
Main circuit power supply: 3-phase (3-wire) 380 to 500 V (allowable variation range) 323 to 550 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | |||||||||
Power supply equipment capacity (kVA) *2 | VLD | 3.7 | 4.9 | 7.5 | 11.4 | 15.9 | 22.7 | ||
LD | 2.8 | 4.4 | 6.1 | 10.1 | 14.5 | 20.0 | |||
ND | 2.3 | 3.6 | 5.0 | 8.3 | 13.4 | 17.2 | |||
Carrier frequency range *3 | VLD | 0.5 to 10.0 kHz | |||||||
LD | 0.5 to 12.0 kHz | ||||||||
ND | 0.5 to 16.0 kHz | ||||||||
Motor start torque *4 | 200%/0.3 Hz | ||||||||
Braking | Regenerative braking | Equipped with braking resistance circuit (with a discharging resistor separately installed) | |||||||
Minimum resistance that can be connected (Ω) | 100 | 100 | 100 | 70 | 70 | 35 | |||
Dimen- sion | Height (mm) | 255 | 255 | 255 | 255 | 260 | 260 | ||
Width (mm) | 150 | 150 | 150 | 150 | 210 | 210 | |||
Depth (mm) | 140 | 140 | 140 | 140 | 170 | 170 | |||
Protective construction | IP20 *5 / UL open type | ||||||||
Approximate mass (kg) | 3 | 3 | 3 | 3 | 6 | 6 |
3G3RX2-[][][][][] | A4110 | A4150 | A4185 | A4220 | A4300 | A4370 | |||
---|---|---|---|---|---|---|---|---|---|
Applicable motor (4-pole) capacity (kW) | VLD | 15 | 18.5 | 22 | 30 | 37 | 45 | ||
LD | 15 | 18.5 | 22 | 30 | 37 | 45 | |||
ND | 11 | 15 | 18.5 | 22 | 30 | 37 | |||
Output | Rated output current (A) | VLD | 31.0 | 40.0 | 47.0 | 62.0 | 77.0 | 93.0 | |
LD | 29.0 | 37.0 | 43.0 | 57.0 | 70.0 | 85.0 | |||
ND | 25.0 | 32.0 | 39.0 | 48.0 | 61.0 | 75.0 | |||
Overload current rating | VLD | 110% 60 sec / 120% 3 sec | |||||||
LD | 120% 60 sec / 150% 3 sec | ||||||||
ND | 150% 60 sec / 200% 3 sec | ||||||||
Rated output voltage | 3-phase (3-wire) 380 to 500 V (depending on receiving voltage) | ||||||||
Rated capacity (kVA) | 400 V | VLD | 21.5 | 27.7 | 32.6 | 43.0 | 53.3 | 64.4 | |
LD | 20.1 | 25.6 | 29.8 | 39.5 | 48.5 | 58.9 | |||
ND | 17.3 | 22.2 | 27.0 | 33.3 | 42.3 | 52.0 | |||
500 V | VLD | 26.8 | 34.6 | 40.7 | 53.7 | 66.7 | 80.5 | ||
LD | 25.1 | 32.0 | 37.2 | 49.4 | 60.6 | 73.6 | |||
ND | 21.7 | 27.7 | 33.8 | 41.6 | 52.8 | 65.0 | |||
Input | Rated input current (A) *1 | VLD | 36.9 | 47.6 | 56.0 | 73.8 | 91.7 | 110.7 | |
LD | 34.5 | 44.0 | 51.2 | 67.9 | 83.3 | 101.2 | |||
ND | 29.8 | 38.1 | 46.4 | 57.1 | 72.6 | 89.3 | |||
Rated input AC voltage | Control power supply: Power supply single phase 380 to 500 V (allowable variation range 323 to 550 V), 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | ||||||||
Main circuit power supply: 3-phase (3-wire) 380 to 500 V (allowable variation range) 323 to 550 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | |||||||||
Power supply equipment capacity (kVA) *2 | VLD | 28.1 | 36.3 | 42.6 | 56.3 | 69.9 | 84.4 | ||
LD | 26.3 | 33.6 | 39.0 | 51.7 | 63.5 | 77.1 | |||
ND | 22.7 | 29.0 | 35.4 | 43.5 | 55.3 | 68.0 | |||
Carrier frequency range *3 | VLD | 0.5 to 10.0 kHz | |||||||
LD | 0.5 to 12.0 kHz | ||||||||
ND | 0.5 to 16.0 kHz | ||||||||
Motor start torque *4 | 200%/0.3 Hz | ||||||||
Braking | Regenerative braking | Equipped with braking resistance circuit (with a discharging resistor separately installed) | |||||||
Minimum resistance that can be connected (Ω) | 35 | 24 | 24 | 20 | 15 | 15 | |||
Dimen- sion | Height (mm) | 260 | 390 | 390 | 390 | 540 | 550 | ||
Width (mm) | 210 | 245 | 245 | 245 | 300 | 390 | |||
Depth (mm) | 170 | 190 | 190 | 190 | 195 | 250 | |||
Protective construction | IP20 *5 / UL open type | ||||||||
Approximate mass (kg) | 6 | 8.5 | 8.5 | 8.5 | 22 | 31 |
3G3RX2-[][][][][] | A4450 | A4550 | B4750 | B4900 | B411K | B413K | |||
---|---|---|---|---|---|---|---|---|---|
Applicable motor (4-pole) capacity (kW) | VLD | 55 | 75 | 90 | 110 | 132 | 160 | ||
LD | 55 | 75 | 90 | 110 | 132 | 160 | |||
ND | 45 | 55 | 75 | 90 | 110 | 132 | |||
Output | Rated output current (A) | VLD | 116 | 147 | 176 | 213 | 252 | 316 | |
LD | 105 | 135 | 160 | 195 | 230 | 290 | |||
ND | 91.0 | 112 | 150 | 180 | 217 | 260 | |||
Overload current rating | VLD | 110% 60 sec / 120% 3 sec | |||||||
LD | 120% 60 sec / 150% 3 sec | ||||||||
ND | 150% 60 sec / 200% 3 sec | ||||||||
Rated output voltage | 3-phase (3-wire) 380 to 500 V (depending on receiving voltage) | ||||||||
Rated capacity (kVA) | 400 V | VLD | 80.4 | 101.8 | 121.9 | 147.6 | 174.6 | 218.9 | |
LD | 72.7 | 93.5 | 110.9 | 135.1 | 159.3 | 200.9 | |||
ND | 63.0 | 77.6 | 103.9 | 124.7 | 150.3 | 180.1 | |||
500 V | VLD | 100.5 | 127.3 | 152.4 | 184.5 | 218.2 | 273.7 | ||
LD | 90.9 | 116.9 | 138.6 | 168.9 | 199.2 | 251.1 | |||
ND | 78.8 | 97.0 | 129.9 | 155.9 | 187.9 | 225.2 | |||
Input | Rated input current (A) *1 | VLD | 138.1 | 175.0 | 209.5 | 253.6 | 300.0 | 376.2 | |
LD | 125.0 | 160.7 | 190.5 | 232.1 | 273.8 | 345.2 | |||
ND | 108.3 | 133.3 | 178.6 | 214.3 | 258.3 | 309.5 | |||
Rated input AC voltage | Control power supply: Power supply single phase 380 to 500 V (allowable variation range 323 to 550 V), 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | ||||||||
Main circuit power supply: 3-phase (3-wire) 380 to 500 V (allowable variation range) 323 to 550 V, 50 Hz (allowable variation range: 47.5 to 52.5 Hz)/60 Hz (allowable variation range: 57 to 63 Hz) | |||||||||
Power supply equipment capacity (kVA) *2 | VLD | 105.2 | 133.4 | 159.7 | 193.2 | 228.6 | 286.7 | ||
LD | 95.3 | 122.5 | 145.2 | 176.9 | 208.7 | 263.1 | |||
ND | 82.6 | 101.6 | 136.1 | 163.3 | 196.9 | 235.9 | |||
Carrier frequency range *3 | VLD | 0.5 to 10.0 kHz | 0.5 to 8.0 kHz | ||||||
LD | 0.5 to 12.0 kHz | 0.5 to 8.0 kHz | |||||||
ND | 0.5 to 16.0 kHz | 0.5 to 10.0 kHz | |||||||
Motor start torque *4 | 200%/0.3 Hz | 180%/0.3 Hz | |||||||
Braking | Regenerative braking | Regenerative braking unit separately installed | |||||||
Minimum resistance that can be connected (Ω) | 10 | 10 | — | — | — | — | |||
Dimen- sion | Height (mm) | 550 | 550 | 700 | 700 | 740 | 740 | ||
Width (mm) | 390 | 390 | 390 | 390 | 480 | 480 | |||
Depth (mm) | 250 | 250 | 270 | 270 | 270 | 270 | |||
Protective construction | IP20 *5 / UL open type | IP00 / UL open type | |||||||
Approximate mass (kg) | 31 | 31 | 41 | 41 | 53 | 53 |
Tim tehnikal kami terdiri dari para ahli yang berpengalaman dalam bidang Sensing Devices, Programmable Controllers, Control Components, dan produk Omron lainnya. Dengan pengetahuan yang kami miliki, kami dapat membantu customer untuk mengubah sistem pabrik yang konvensional menjadi suatu sistem yang bebas masalah, otomatis, dan dengan sistem pemantauan yang mudah.